Okuda, Yukihiko; Kang, Z.; Nishida, Akemi; Tsubota, Haruji; Li, Y.
Doboku Gakkai Dai-13-Kai Kozobutsu No Shogeki Mondai Ni Kansuru Shinpojiumu Rombunshu (Internet), 8 Pages, 2022/01
In case missiles crash into reactor buildings of nuclear power plants, stress waves due to the missile impacts propagate from the impacted wall to the interior of the structure. Stress waves are likely to excite high-frequency vibrations of internal equipment in the reactor building, so it is an important issue to assess the damage against missile impact for safety related internal equipment. The OECD/NEA launched the IRIS benchmark project in order to assess the response for nuclear facility by projectile impact and the third phase of IRIS (IRIS 3) contributes to the investigation on the dynamic response of reinforced concrete (RC) structure with internal equipment. We participated in the IRIS3 and have conducted the calibration analysis for projectile impact test of the structure which models a reactor building and internal equipment. This paper presents simulation and test results from dynamic response of the RC structure with internal equipment.